| 1 | Profile A: Residential Branch Protection | Miniature Circuit Breaker (MCB) | IEC 60898-1; EN 60898-1; applicable national adoption | 230/400 V AC | Typically 1–63 A | Commonly 4.5–10 kA, depending on model | B, C, or D tripping curves; 1P, 1P+N, 2P, 3P, and 4P versions; DIN-rail mounting; thermal-magnetic protection |
| 2 | Profile B: Commercial Distribution Protection | Molded Case Circuit Breaker (MCCB) | IEC 60947-2; EN 60947-2; UL 489 where applicable | Up to approximately 690 V AC | Typically 16–1,600 A | Approximately 18–150 kA, depending on frame and voltage | Adjustable thermal-magnetic or electronic trip units; accessories; line-load flexibility; insulation and isolation functions |
| 3 | Profile C: Low-Voltage Main-Incomer Protection | Air Circuit Breaker (ACB) | IEC 60947-2; EN 60947-2; UL 1066 for relevant applications | Up to approximately 1,000 V AC | Typically 630–6,300 A | Commonly 42–150 kA, subject to frame and test configuration | Draw-out or fixed construction; electronic protection; zone-selective interlocking; communication; maintenance testing |
| 4 | Profile D: Personnel Shock Protection | Residual Current Device (RCCB/RCD) | IEC 61008-1; EN 61008-1; national wiring requirements | 230/400 V AC | Typically 16–125 A | Used with a separate overcurrent protective device | Residual-current sensitivity commonly 10, 30, 100, or 300 mA; Type AC, A, F, or B sensing; test button; selective versions |
| 5 | Profile E: Combined Household Protection | Residual Current Breaker with Overcurrent Protection (RCBO) | IEC 61009-1; EN 61009-1; national wiring requirements | 230 V AC or 230/400 V AC | Typically 6–63 A | Commonly 4.5–10 kA, depending on product design | Overcurrent and residual-current protection in one device; 1P+N or 2P construction; Type A availability; compact DIN-rail format |
| 6 | Profile F: Photovoltaic DC Protection | PV DC Circuit Breaker | IEC 60947-2; IEC 60947-1; IEC 60947-3 for relevant switching applications | Typically 500–1,500 V DC | Typically 10–250 A | DC interrupting performance must be verified at the specified voltage and polarity | DC-rated arc suppression; correct polarity; dedicated PV application; clear isolation position; compatibility with string and array voltages |
| 7 | Profile G: Battery Energy Storage Protection | High-Voltage DC Battery Breaker | IEC 60947-2; IEC 62477-1 for power-electronic system safety; application-specific battery standards | Commonly 500–1,500 V DC | Typically 100–800 A | Must be specified for the battery system's prospective DC fault current | DC short-circuit interruption; pre-charge and contactor coordination; auxiliary contacts; undervoltage or shunt trip options; thermal monitoring compatibility |
| 8 | Profile H: Motor Feeder Protection | Motor Protection Circuit Breaker (MPCB) | IEC 60947-2; IEC 60947-4-1 for motor starters and contactor coordination | Up to approximately 690 V AC | Typically 0.1–100 A, depending on design | Often up to approximately 50 kA at the rated voltage | Adjustable overload setting; magnetic short-circuit protection; phase-loss sensitivity; manual motor control; Type 1 or Type 2 coordination data |
| 9 | Profile I: Compact Equipment Protection | Supplementary Protector or Equipment MCB | IEC 60934 for circuit-breakers for equipment; applicable equipment safety standards | Typically up to 250 V AC or 65 V DC, depending on design | Typically 0.5–63 A | Model-specific; verify the tested interrupting capacity for the intended circuit | Compact footprint; hydraulic-magnetic or thermal-magnetic operation; auxiliary contacts; panel or PCB mounting; suitability for control equipment |
| 10 | Profile J: Industrial Selective Protection | Current-Limiting MCCB or Selective Circuit Breaker | IEC 60947-2; EN 60947-2; UL 489 where applicable | Up to approximately 690 V AC | Typically 100–1,600 A | Often 50–200 kA, subject to tested voltage and configuration | High interrupting capacity; current limitation; adjustable short-time delay; selectivity tables; energy-reduction and coordination options |