| Definition | A telecentric macro lens is an imaging lens designed so that the chief rays in the relevant optical space are parallel to the optical axis. | Chief-ray angle approaches 0° in the designed telecentric space. | It reduces perspective-related size changes and produces more consistent measurements of small objects. |
| Core Purpose | Its primary purpose is to maintain nearly constant magnification when the object moves slightly along the optical axis. | Object-size stability is prioritized over a wide field of view or compact lens size. | This is valuable for dimensional inspection, gauging, and repeatable macro imaging. |
| Object-Space Telecentricity | The entrance pupil is positioned effectively at infinity, causing chief rays on the object side to travel approximately parallel to the optical axis. | Object-space chief-ray angle is approximately 0°. | Object features at different depths appear with much less apparent size variation. |
| Image-Space Telecentricity | The exit pupil is positioned effectively at infinity, making image-side chief rays approximately parallel to the optical axis. | Image-space chief-ray angle is approximately 0°. | It can improve sensor illumination uniformity and support specific optical measurement systems. |
| Bi-Telecentric Design | A bi-telecentric lens is telecentric in both object space and image space. | Both object-side and image-side chief-ray angles approach 0°. | It provides high magnification stability and is commonly selected for precision machine-vision measurement. |
| Perspective Distortion | Perspective distortion is strongly reduced because the imaging geometry does not significantly change with small object-distance variations. | Lower apparent size change than with a conventional macro lens at comparable magnification. | Edges, diameters, gaps, and other measurable features are easier to compare reliably. |
| Magnification Stability | Magnification remains substantially more stable when the object is displaced along the optical axis within the specified working range. | Residual variation depends on lens design, focus position, aperture, and object displacement. | It reduces measurement error caused by small fixture-height or part-position differences. |
| Working Distance | Working distance is the physical distance from the lens reference point or front optical surface to the object, depending on the manufacturer’s specification method. | Usually fixed or tightly specified for a given telecentric lens model. | A stable working distance simplifies lighting, fixturing, and repeatable inspection setups. |
| Magnification Range | Telecentric macro lenses are generally optimized for a defined magnification rather than a large zoom range. | Common machine-vision magnifications include approximately 0.1× to 1×; specialized systems may extend beyond this range. | The selected magnification determines the object field of view and measurement resolution. |
| Field of View | The field of view is determined by sensor dimensions and optical magnification. | Field of view ≈ sensor dimension ÷ magnification. | A higher magnification gives a smaller field of view, while a lower magnification covers a larger area. |
| Depth of Field | Depth of field is the object-space range that appears acceptably sharp. Telecentricity itself does not automatically create unlimited depth of field. | Depth of field depends mainly on magnification, f-number, wavelength, sensor resolution, and acceptable blur. | Stopping down can increase depth of field, but it also reduces light and may increase diffraction blur. |
| Aperture Control | The aperture controls light transmission, depth of field, and diffraction behavior. | Higher f-numbers generally increase depth of field but reduce available light. | Choosing the aperture requires balancing sharpness, exposure time, diffraction, and inspection speed. |
| Parallax | Parallax is the apparent displacement of features caused by changes in viewing angle. Telecentric object-space geometry minimizes this effect. | Very small parallax within the specified object-space range. | Parts with height differences can be measured with less lateral position error. |
| Lighting Compatibility | Telecentric imaging is often paired with coaxial, dome, diffuse, or backlighting arrangements according to the object’s surface and measurement goal. | Backlighting is especially effective for silhouettes, holes, widths, and outer profiles. | Good lighting preserves edge contrast and can be as important as lens resolution for measurement accuracy. |
| Image Uniformity | Telecentric optical layouts can provide more uniform geometric projection and, in suitable designs, improved illumination consistency across the sensor. | Uniformity varies with lens design, aperture, sensor format, and illumination setup. | More consistent image geometry supports thresholding, edge detection, and dimensional analysis. |
| Resolution | Resolution is determined by the lens, sensor pixel size, numerical aperture, illumination wavelength, focus, and image-processing conditions. | Telecentricity improves geometric consistency but does not by itself guarantee higher optical resolution. | The lens and sensor must be matched to the smallest feature that must be detected or measured. |
| Trade-Offs | Telecentric lenses typically require more optical elements and a larger optical path than conventional macro lenses. | Common trade-offs include greater size, weight, cost, and a narrower operating range. | They are most justified when measurement repeatability is more important than portability or flexibility. |
| Best-Suited Applications | Typical uses include dimensional inspection, semiconductor and electronics inspection, pharmaceutical packaging checks, part-profile analysis, and precision assembly verification. | Most useful when object size, edge location, or feature position must be measured consistently. | The controlled projection reduces errors caused by perspective and minor object-position changes. |
| Selection Criteria | Selection should consider sensor size, required field of view, magnification, working distance, object depth, resolution, lighting, and acceptable measurement tolerance. | The lens specification must cover the complete object field and the required telecentric object-space range. | A correct system match is necessary to obtain the expected accuracy and avoid vignetting or insufficient coverage. |